Carbon Dioxide Fire Extinguishers (CO2) According to NFPA 10

 Carbon Dioxide Fire Extinguishers

CO2 Fire Extinguishers According to NFPA
CO2 Fire Extinguishers According to NFPA



Carbon Dioxide Agent:

Carbon dioxide is a compressed gas agent and is commonly referred to as CO2, the agent is retained as a liquid at 800 to 900 psi at temperatures below 31°C, and is self-expelling.

Matching Hazard to carbon dioxide extinguishers:

Although rated for use on Class B and C fires, it is often effectively used on small Class A fires.

How Carbon Dioxide Extinguishes Fire?

  1. Carbon dioxide prevents combustion by displacing the oxygen in the air surrounding a fire.
  2. Cooling the fuel, The rapid expansion and pressure reduction of the pressurized liquid carbon dioxide in the cylinder results in the cooling and refrigeration effect.

Advantages:

  • CO2 extinguishers don't leave a residue, a consideration that may be important in laboratories and in areas in which food is prepared or electronic equipment is present.

Disadvantages

  • CO2 extinguishers have a relatively short range because the agent is expelled in the form of a gas/snow cloud.
  • CO2 extinguishers are affected by wind or drafts.
  • If CO2 extinguishers are used in a confined or unventilated area, precautions should be taken so that people are not overcome from lack of oxygen.

Characteristics of CO2 Extinguishers:

For the various sizes, stream ranges, discharge times, temperature requirements, and ratings of carbon dioxide extinguishers available, see the below table:
CO2 FIRE EXTINGUISHER CHARACTERISTICS
CO2 FIRE EXTINGUISHER CHARACTERISTICS



CO2 Extinguisher Components:

  1. pressure cylinder, or shell
  2. siphon tube
  3. valve for releasing the agent
  4. discharge horn or horn-hose combination.

How to operate CO2 Fire Extinguisher:

  • Hold the CO2 extinguisher upright by its carrying handle, remove the locking pin, and squeeze the operating lever.
  • In smaller portable models, the discharge horn often is connected to the valve assembly by a metal tube/swing joint connector, it may be operated with one hand.
  • Larger portable models require two hands, and their discharge horns are attached to a length of hose.
  • Wheeled extinguishers have a cylinder valve with a locking ring pin, a long hose of (4 to 12 m), and a projector that consists of a horn, a long handle, and a control valve. Once the cylinder valve has been opened, the operator controls the discharge with the valve on the projector handle.


References of this article:

NFPA-10 - 2018 edition (Standard for Portable Fire Extinguishers)

5 comments:

  1. You own use a crucial children.. Blesss suitable working with.. Pictures will definitely analyze advanced most up to date orders placed this particular website.. keep on keeping.. c tec fire alarm

    ReplyDelete
  2. Paper protection is reasonable for all hard surfaces and versatile surfaces yet doesn't function admirably to ensure rugs as it can tear while flexing under strides. Paper items are breathable so that paste exhaust and concrete relieving fumes can get away. EMF Protectors

    ReplyDelete
  3. This comment has been removed by the author.

    ReplyDelete
  4. Regular fire drills and evacuation plans are essential to ensure preparedness in case of an emergency.
    Fire Suppression Systems

    ReplyDelete