According to NFPA 13 - 2022 edition (28.5.2.1.1), Branch lines shall not exceed eight sprinklers on either side of a cross main and shall be sized in accordance with the tables below for light and ordinary hazard occupancies:


Pipe Schedule for Light Hazard
Pipe Schedule for Light Hazard

Pipe Schedule for Ordinary Hazard
Pipe Schedule for Ordinary Hazard


Where more than eight sprinklers on a branch line are necessary, lines shall be permitted to be increased to nine sprinklers by making the two end lengths 1 in. and 11∕4 in. , respectively, and the sizes thereafter standard.

Ten sprinklers shall be permitted to be placed on a branch line, making the two end lengths 1 in. and 11∕4 in., respectively, and feeding the tenth sprinkler by a 21∕2 in. pipe.